Field - stf
Control section flags
- Map: SMF70CTL
- Based on: SMF70STF
Control section flags
This is a flag field with the following bit fields:
Field | Bit-Position | Description |
---|---|---|
store_sys_info | 0 | Store-system-information facility installed |
cpu_adjustment_factor_chng | 1 | Physical CPU adjustment factor changed |
su_available | 2 | Service units available to MVS image changed |
rcu | 3 | SMF70LAC is provided for systems running in LPAR mode, as a z/VM guest, or under an alternate virtual machine. The value does no longer include CPU wait times. |
hwv | 4 | SMF70MDL is the model-capacity identifier and SMF70HWM is the physical model. If OFF, SMF70MDL represents both model-capacity identifier and physical model |
cp_promote_slices | 5 | CP promote slices (OPT parameter BLWLTRPCT) changed |
starvation_threshold | 6 | Swapped-in starvation threshold (OPT parameter BLWLINTHD) changed |
gav | 7 | SMF70GAU is valid |