IBM SMF Explorer
GitHubToggle Dark/Light/Auto modeToggle Dark/Light/Auto modeToggle Dark/Light/Auto modeBack to homepage

SMF 74 Subtype 5

Virtual fields

NameBased onDescription
timestampdate
time
Record Timestamp
boost_classflaBoost class is set at end of interval, valid only when zIIP boost and/or Speed boost is active: 001 IPL, 010 Shutdown, 011 Recovery Process

Record fields

NameBased onDescriptionType/Format
dateSMF74DTEDate of Recorddate
timeSMF74TMETime of Recordtime
timestamp virtualdate
time
Record Timestamp
lenSMF74LENSMF RECORD LENGTH. ZERO AFTER GRBSMFR REASSEMBLYinteger
segSMF74SEGSEGMENT DESCRIPTORinteger
flg flagSMF74FLGSYSTEM INDICATOR FLAGSstring
rrfflgNEW RECORD FORMAT
sutflgSUBTYPES USED
v4flgMVS/ESA V4 IF ON
esaflgMVS/ESA IF ON
vxaflgMVS/XA IF ON
osflgOPERATING SYSTEM IS OS/VS2
bfyflgSYSTEM RUNNING IN PR/SM MODE
rtySMF74RTYRECORD TYPEinteger
tmeSMF74TMETIME RECORD WRITTENtime
dteSMF74DTEDATE RECORD WRITTENdate
sidSMF74SIDSYSTEM ID FROM INSTALLATIONstring
ssiSMF74SSISUBSYSTEM ID (RMF )string
stySMF74STYSUBTYPEinteger
trnSMF74TRNNUMBER OF TRIPLETS IN THIS RECinteger
prsSMF74PRSOFFSET TO RMF PRODUCT SECTIONinteger
prlSMF74PRLLENGTH OF RMF PRODUCT SECTIONinteger
prnSMF74PRNNUMBER OF RMF PRODUCT SECTIONSinteger
coSMF745COOffset to control sectioninteger
clSMF745CLLength of control sectioninteger
cnSMF745CNNumber of control sectionsinteger
doSMF745DOOffset to CACHE device data sectioninteger
dlSMF745DLLength of CACHE device data sectioninteger
dnSMF745DNNumber of CACHE device data sectionsinteger
xoSMF745XOOffset to CACHE device data section extensioninteger
xlSMF745XLLength of CACHE device data section extensioninteger
xnSMF745XNNumber of CACHE device data section extensionsinteger
soSMF745SOOffset to CACHE status data sectioninteger
slSMF745SLLength of CACHE status data sectioninteger
snSMF745SNNumber of CACHE status data sectionsinteger
_1oSMF7451OOffset to RAID rank data sectioninteger
_1lSMF7451LLength of RAID rank data sectioninteger
_1nSMF7451NNumber of RAID rank data sectionsinteger

Maps and sections

SMF74PRO

RMF Product Section

NameBased onDescriptionType/Format
mfvSMF74MFVRMF version numberinteger
prdSMF74PRDProduct namestring
istSMF74ISTTime monitor interval starttime
datSMF74DATDate monitor interval startdate
intSMF74INTDuration of monitor intervaltime
samSMF74SAMNumber of samplesinteger
fla flagSMF74FLAFlagsstring
cnvflaData converted from version 2
issflaInvalid samples to be skipped
m3rflaRecord was written by RMF Monitor III
ismflaInterval was under SMF control
rclflaSMF record converted to lower service level. Bit is set by SMF record retrieval service GRBSMFR.
rchflaSMF record converted to higher release or service level. Bit is set by SMF record retrieval service GRBSMFR.
altvmflaRunning under an alternate virtual machine environment
iipflazIIP boost was active during entire interval
eedflaSpeed boost was active during entire interval
boost_class virtualflaBoost class is set at end of interval, valid only when zIIP boost and/or Speed boost is active: 001 IPL, 010 Shutdown, 011 Recovery Process
cycSMF74CYCSampling cycle lengthtime
mvsSMF74MVSMVS software level (consists of an acronym and the version, release, and modification level - ZVvvrrmm)string
imlSMF74IMLIndicates the type of processor complex on which data measurements were taken. X'03’ = 9672, zSeriesinteger
prf flagSMF74PRFProcessor flagsstring
qesprfSystem has expanded storage
cneprfEquipped with ESCON channel
drcprfESCON Director in configuration
emeprfSystem in z/ARCH mode
priprfAt least one zAAP is currently installed
prpprfAt least one zIIP is currently installed
pedprfEnhanced DAT facility 1
pe2prfEnhanced DAT facility 2
ptnSMF74PTNPR/SM partition numberstring
srlSMF74SRLSMF record levelinteger
ietSMF74IETInterval expiration time tokenstring
lgoSMF74LGOOffset GMT to local timeinteger
raoSMF74RAOOffset to reassembly area relative to start of RMF product sectioninteger
ralSMF74RALLength of reassembly area. Area consists of a fixed header and a variable number of information blocks. Length depends on the record type/subtype, but is fixed for a specific type/subtypeinteger
ranSMF74RANNumber of reassembly area. This field is used to indicate whether SMF record is broken. If 0, record is not broken. If 1, record is broken. Offset and length are only valid if SMFxxRAN is 1. Reassembly area is only present in broken records.integer
oilSMF74OILOriginal interval length as defined in the session or by SMF (in seconds)integer
synSMF74SYNSYNC value in secondsinteger
gieSMF74GIEProjected gathering interval end GMT timedate-time
xnmSMF74XNMSysplex name as defined in ECVTSPLXstring
snmSMF74SNMSystem name for current system as defined in CVTSNAMEstring

R745CNTL

Cache Control Section

NameBased onDescriptionType/Format
r745clvlR745CLVLGatherer levelinteger
r745cmdlR745CMDLCaching subsystem modelinteger
r745ccntR745CCNTRecord sequence numberinteger
r745cuidR745CUIDReal CU type code. If R745CMDL=1, configured CU type codestring
r745cscR745CSCStatus code 00 = successful processed, 04 = IOS return code R745CIOC ^= 0, 08 = IDCSS01 return code R745CRTN ^= 0, 98 = SYSTEM or USER ABEND R745CEA ^= 0integer
r745caeR745CAEABEND CODE (SDWACMPC). System and User completion code (12 bits each)string
r745crtnR745CRTNIDCSS01 return code. If not zero, no device data sections. SMF745DN = 0integer
r745ciocR745CIOCIOS return code. If not zero, no device data sections. SMF745DN = 0integer
r745cintR745CINTNumber of seconds since subsystem statistics last collectedinteger
r745cfdvR745CFDVFailing deviceinteger
nedtypenNEDTYPENType numberstring
nedmodnNEDMODNModel numberstring
nedmanufNEDMANUFManufacturerstring
nedpmanuNEDPMANUPlant of manufacturestring
nedseqnNEDSEQNSequence numberstring
nedtagNEDTAGTaginteger

R745DEV

Cache Device Data Section

NameBased onDescriptionType/Format
r745dvolR745DVOLVolume serial of devicestring
r745dfl4 flagR745DFL4Flagsstring
r745dev4r745dfl4B'1’ 4 digit device addr.
r745dscsR745DSCSSubchannel set ID 00 - Subchannel set ID 0 01 - Subchannel set ID 1 10 - Subchannel set ID 2 11 - Subchannel set ID 3string
r745dccuR745DCCUConfigured control unit type code if R745CMDL = 1string
r745duntR745DUNTUnit addr. for sense CMDstring
r745devnR745DEVNDevice number (binary)string
r745dflg flagR745DFLGFlagsstring
r745dnavr745dflgCache storage not available set to 0 for DS8000
r745dpdfR745DPDFFormat of Performance Data returned B'000’ = 3990 Format B'001’ = DS8000 Disk Controller Formatstring
r745dfrmR745DFRMFormat of data returned B'0000’ = 3990 Models 1,2 and 3 or Basic Operation Mode B'0001’ = 3990 Model 6 Enhanced Operation Mode 1 or host supports DS8000 Disk Controllerstring
r745dvidR745DVIDDevice addressinteger
r745dvs1R745DVS1Addressed device status 1string
r745dsdvR745DSDVDevice caching status B'00’ = Caching activatedstring
r745dsfw flagR745DSFWDASD fast write device status B'00’ = DFW allowedstring
r745dspdr745dsfwPPRC copy pair suspended
r745dssdr745dsfwPPRC copy pair is duplex pending
r745dsdpR745DSDPPPRC pair status B'00’ = PPRC pair available (full duplex) B'01’ = PPRC pair pending B'10’ = Not used B'11’ = Suspendedstring
r745dvs2R745DVS2Addressed device status 2 If R745SFT = 0 Pinned data (2 bits) 00.. …. No pinned data 01.. …. Pinned data exists for device 10.. …. Reserved 11.. …. Not used ..xx xx.. Not used …. ..1. Advanced FlashCopy enabled …. …1 FlashCopy volume enabled If R745SFT = 1 or 2 Global Mirror State (3 bits) 000. …. No Global Mirror configured 001. …. Global Mirror running optimal 010. …. Global Mirror running suboptimal 011. …. Global Mirror running Consistency Groups failing 100. …. Global Mirror paused 101. …. Global Mirror fatal 110. …. More than 1 Global Mirror session running in the box 111. …. Reserved …1 …. Session Member pending …. 1… Volume not allowed online …. .1.. Reserved …. ..1. Advanced FlashCopy enabled …. …1 FlashCopy volume enabledstring
r745drcrR745DRCRSearch read caching requ. Floating point shortnumber
r745dcrhR745DCRHSearch read caching hits Floating point shortnumber
r745dwrcR745DWRCWrite caching requests Floating point shortnumber
r745dwchR745DWCHWrite caching requ. hits Floating point shortnumber
r745drsrR745DRSRRead sequential requests Floating point shortnumber
r745drshR745DRSHRead sequential requ.hits Floating point shortnumber
r745dwsrR745DWSRWrite sequential requests Floating point shortnumber
r745dwshR745DWSHWrite sequ. request hits Floating point shortnumber
r745drnrR745DRNRSearch read non-retentive requests Floating point shortnumber
r745dnrhR745DNRHSearch read non-retentive request hits Floating point shortnumber
r745dwnrR745DWNRWrite non-retentive requests Floating point shortnumber
r745dwnhR745DWNHWrite non-retentive hits Floating point shortnumber
r745diclR745DICLInhibit cache load req. Floating point shortnumber
r745dbcrR745DBCRBypass cache requests Floating point shortnumber
r745dtcR745DTCSeq DASD to cache XFRs Floating point shortnumber
r745dntdR745DNTDNormal cache requests DASD to CACHE XFRs Floating point shortnumber
r745dctdR745DCTDCACHE to DASD XFRs Floating point shortnumber
r745dfwbR745DFWBDASD Fast Write operations delayed due to non-volatile storage space constraints Floating point shortnumber
r745dfwcR745DFWCFast write caching req. Floating point shortnumber
r745dfwsR745DFWSFast write sequ. req. Floating point shortnumber
r745dcrmR745DCRMRecord cache read misses Floating point shortnumber
r745dsg2R745DSG2Device status group 2 …. 1… Device in a SPID Fenced state …. .1.. Volume is part of a RAID rank that is undergoing RAID rebuildstring
r745dcol flagR745DCOLVolume Space Management B'00’ = Standard volume B'01’ = Track Space Efficient Volume B'10’ = Extent Space Efficient Volume B'11’ = Reservedstring
r745defnr745dcolData exits in failed NVS
r745dbdpr745dcolDevice in a Soft Fenced state
r745dpdtR745DPDTIf R745SFT = 1 or 2 Pinned data B'00’ = No pinned data B'01’ = Pinned data exists for the device B'10’ = Reserved B'11’ = Not usedstring
r745dsidR745DSIDSubsystem IDstring
r745dcwpR745DCWPRCD cache write promotions Floating point shortnumber
r745dkdwR745DKDWCKD writes, collected for 3990-03/06, 2105 Floating point shortnumber
r745dkdhR745DKDHCKD write hits, collected for 3990-03/06, 2105 Floating point shortnumber
r745dfwrR745DFWROperations delayed due to cache space constraints Floating point shortnumber

R745XDEV

Cache Device Data Section Extension

NameBased onDescriptionType/Format
r745xdvnR745XDVNDevice number (binary)string
r745xscsR745XSCSSubchannel set IDinteger
r745xrsvR745XRSVLower interface I/O msecstring
r745xctcR745XCTCNot Used by RMFstring
r745xctrR745XCTRNot used by RMFstring
r745xvrdR745XVRDNot used by RMFstring
r745xvrhR745XVRHNot used by RMFstring
r745xvwrR745XVWRNot used by RMFstring
r745xvwhR745XVWHNot used by RMFstring
r745xsrrR745XSRRNot used by RMFstring
r745xfrdR745XFRDNot used by RMFstring
r745xwccR745XWCCNot used by RMFstring
r745xprcR745XPRCNot used by RMFstring
r745xct1R745XCT1Not used by RMFstring
r745xct2R745XCT2Not used by RMFstring
r745xct3R745XCT3Not used by RMFstring
r745xct4R745XCT4Not used by RMFstring
r745xct5R745XCT5Not used by RMFstring
r745xct6R745XCT6Not used by RMFstring
r745xct7R745XCT7Not used by RMFstring
r745xct8R745XCT8Not used by RMFstring
r745xct9R745XCT9Not used by RMFstring
r745xctaR745XCTANot used by RMFstring

R745STAT

Cache Status Data Section

NameBased onDescriptionType/Format
r745svolR745SVOLVolume serial of devicestring
r745suntR745SUNTUnit addr. for sense CMDstring
r745sdevR745SDEVDevice number (binary)string
r745slnR745SLNLength of data sectioninteger
r745sftR745SFTStatus data format B’….0000’ = 40 bytes sense B’…….1’ = 44 bytes sense/ unit KB B’……10’ = 96 bytes sense/ unit KBstring
r745sdidR745SDIDDevice IDstring
r745snadR745SNADNum. of attached devicesinteger
r745snssR745SNSSNum. of statistic setsinteger
r745scsR745SCSCaching status …1 …. Reserved …. 1… Storage Facility running as a single cluster …. .1.. Must be zero …. ..1. Reservedstring
r745sos flagR745SOSOverall caching status B'000’ = Caching active B'001’ = Reserved B'010’ = Subsystem error B'011’- B'111’ = Reservedstring
r745snrr745sosNon-retentive deactivated
r745sdsr745sosDisabled for maintenance (No longer used)
r745simr745sosIML device not available (no longer used)
r745svss flagR745SVSSNon-volatile storage stat.string
r745snhtr745svssHost termination
r745snisr745svssProblem termination
r745dfwir745svssDFW inhibited
r745sndsr745svssDisabled for maintenance
r745snper745svssPending due to problem
r745sclnR745SCLNLng.of subsys. count areainteger
r745scsfR745SCSFState of Copy Services Functioninteger
r745scnfR745SCNFConfigured subsystem storage if R745SFT = 0 in bytes if R745SFT = 1 or 2 in KBinteger
r745savlR745SAVLAvailable subsystem storage if R745SFT = 0 in bytes if R745SFT = 1 or 2 in KBinteger
r745spinR745SPINPinned subsystem storage,collected for if R745SFT = 0 in bytes if R745SFT = 1 or 2 in KBinteger
r745soffR745SOFFOffline subsystem storage, collected for if R745SFT = 0 in bytes if R745SFT = 1 or 2 in KBinteger
r745sds1R745SDS1Addressed device status 1string
r745sdcsR745SDCSDevice caching status B'00’ = Caching activatedstring
r745sdfw flagR745SDFWDASD fast write status B'00’ = DFW allowedstring
r745spdpr745sdfwPPRC copy pair suspended
r745ssdpr745sdfwPPRC copy pair is duplex pending
r745sdpsR745SDPSPPRC pair status B'00’ = PPRC pair available (full duplex) B'01’ = PPRC pair pending B'10’ = Not used B'11’ = Suspendedstring
r745sds2 flagR745SDS2Addressed device status 2 If R745SFT = 0 Pinned data (2 bits) 00.. …. No pinned data 01.. …. Pinned data exists for device 10.. …. Reserved 11.. …. Not used ..xx xx.. Not used …. ..1. Advanced FlashCopy enabled …. …1 FlashCopy volume enabled If R745SFT = 1 or 2 Global Mirror State (3 bits) 000. …. No Global Mirror configured 001. …. Global Mirror running optimal 010. …. Global Mirror running suboptimal 011. …. Global Mirror running Consistency Groups failing 100. …. Global Mirror paused 101. …. Global Mirror fatal 110. …. More than 1 Global Mirror session running in the box 111. …. Reserved …1 …. Session Member pending …. 1… Volume not allowed online …. .1.. Reserved …. ..1. Advanced FlashCopy enabled …. …1 FlashCopy volume enabledstring
r745sdpnr745sds2Pinned data (no longer used)
r745sfdpr745sds2Device is failed duplex (no longer used)
r745scnvR745SCNVConfig. non-volatile cache, collected for if R745SFT = 0 in bytes if R745SFT = 1 or 2 in KBinteger
r745spndR745SPNDPinned non-volatile cache, collected for if R745SFT = 0 in bytes if R745SFT = 1 or 2 in KBinteger
r745sg2R745SG2Device status group 2 …. 1… Device in a SPID Fenced state …. .1.. Volume is part of a RAID rank that is undergoing RAID rebuildstring
r745scol flagR745SCOLColume Space Management B'00’ = Standard volume B'01’ = Track Space Efficient Volume B'10’ = Extent Space Efficient Volume B'11’ = Reservedstring
r745sfvsr745scolData on failed NVS
r745sdbpr745scolDevice in a Soft Fenced state pending
r745spdaR745SPDAIf R745SFT = 1 or 2 Pinned data B'00’ = No pinned data B'01’ = Pinned data exists for the device B'10’ = Reserved B'11’ = Not usedstring
r745sglR745SGLGlobal status X'80’ CFW & DFW suspendedstring
r745ssidR745SSIDSubsystem Idstring

R7451DEV

RAID Rank Data Section

NameBased onDescriptionType/Format
r7451dvnR7451DVNDevice number (binary)string
r7451inc flagR7451INCIncrement valuesstring
r7451sior7451inc‘1’ = Synchronous I/O cache data are valid
r7451hpfr7451inczHPF read and write I/O requests available
r7451unt flagR7451UNTUnits: ‘00’ = Bytes in units of 128K. Times in units of 16 milliseconds. ‘01’ = Reserved. ‘10’ = Reserved. ‘11’ = Reserved.string
r7451xflr7451unt‘1’ = Transfer statistics R7451XFR valid
r7451scsR7451SCSSubchannel set IDinteger
r7451rsvR7451RSVLower interface I/O activity in msec (short float). Zero for 2107number
r7451flgR7451FLGInformation in this section: X'00’ = No additional data. X'01’ = RAID rank data. X'02’ = Physical storage data.string
r7451aidR7451AIDDevice adapter ID. Only valid with RAID rank datainteger
r7452xidR7452XIDExtent pool idinteger
r7452xtyR7452XTYExtent type: X'04’ = FB 1Gb. X'84’ = CKD 1Gbstring
r7452xfl flagR7452XFLExtent flagsstring
r7452dxar7452xflDynamic extent allocation
r7452dshr7452xflData sharing
r7452misr7452xflMigrating/migration state
r7451hssR7451HSSHDD sector size. Only valid with RAID rank datainteger
r7452proR7452PROPhysical storage read operations (short float)number
r7452pwoR7452PWOPhysical storage write operations (short float)number
r7452pbrR7452PBRPhysical storage bytes read (short float). Units in R7451UNTnumber
r7452pbwR7452PBWPhysical storage bytes written (short float). Units in R7451UNTnumber
r7451rmrR7451RMRRecord mode read request (short float)number
r7451xsfR7451XSFXRC or CC sidefile reads (short float)number
r7451xcwR7451XCWXRC or CC contaminated writes (short float)number
r7451tspR7451TSPNumber of tracks transferred to secondary PPRC volume (short float)number
r7451nvsR7451NVSNVS space allocation (short float)number
r7452prtR7452PRTPhysical storage read response time (short float). Units in R7451UNTnumber
r7452pwtR7452PWTPhysical storage write response time (short float). Units in R7451UNTnumber
r7451ct1R7451CT1Bytes read (short float). Units in R7451UNTnumber
r7451ct2R7451CT2Bytes written (short float). Units in R7451UNTnumber
r7451ct3R7451CT3Read response time (short float). Units in R7451UNTnumber
r7451ct4R7451CT4Write response time (short float). Units in R7451UNTnumber
r7451ct5R7451CT5z/HPF Read I/O requests (short float)number
r7451ct6R7451CT6z/HPF Write I/O requests (short float)number
r7451zhlR7451ZHLzHPF List Pre-fetch I/O Requests. Number of command chains, where the Transport Mode operation specified a non-zero Imbedded Locate Record Countnumber
r7451zhhR7451ZHHzHPF List Pre-fetch I/O Request Hits. Number of command chains, where - the Transport Mode operation specified a non-zero Imbedded Locate Record Count. - the chain was completed without requiring access to any DDM.number
r7451gsfR7451GSFGlobal Mirror Collisions (GMC) sidefile count (short float). A GMC occurs when, during the sending of data in the secondary to create a consistency group, a subsequent host update is attempted before the modified track has been transmitted to the secondary volume. The modified track will be moved to the sidefile before allowing a new host write. The counter will be incremented by one when a track is added to the sidefile.number
r7451gssR7451GSSGlobal Mirror Collisions Send synchronous count (short float). When a write collision occurs, the modified track data which belongs to the current consistency group may be sent to the remote control unit before allowing the write. The data may come from the sidefile if it is full or from cache if the collision sidefile is not being utilized.number
r7451srrR7451SRRNumber of synchronous I/O cache read requests. (Valid if bit 3 of R7451INC is set.)number
r7451srhR7451SRHNumber of synchronous I/O cache read request hits. (Valid if bit 3 of R7451INC is set.)number
r7451swrR7451SWRNumber of synchronous I/O cache write requests. (Valid if bit 3 of R7451INC is set.)number
r7451swhR7451SWHNumber of synchronous I/O cache write request hits. (Valid if bit 3 of R7451INC is set.)number