SMF 79 Subtype 9
Name | Based on | Description |
---|---|---|
timestamp | date time | Record Timestamp |
boost_class | fla | Boost class is set at end of interval, valid only when zIIP boost and/or Speed boost is active: 001 IPL, 010 Shutdown, 011 Recovery Process |
Name | Based on | Description | Type/Format |
---|---|---|---|
date | SMF79DTE | Date of Record | date |
time | SMF79TME | Time of Record | time |
timestamp virtual | date time | Record Timestamp | |
len | SMF79LEN | SMF RECORD LENGTH. ZERO AFTER GRBSMFR REASSEMBLY | integer |
seg | SMF79SEG | SEGMENT DESCRIPTOR | integer |
flg flag | SMF79FLG | SYSTEM INDICATOR FLAGS | string |
rrf | flg | NEW RECORD FORMAT | |
sut | flg | SUBTYPES USED | |
v4 | flg | MVS/ESA V4 IF ON | |
esa | flg | MVS/ESA IF ON | |
vxa | flg | MVS/XA IF ON | |
os | flg | OPERATING SYSTEM IS OS/VS2 | |
bfy | flg | SYSTEM RUNNING IN PR/SM MODE | |
rty | SMF79RTY | RECORD TYPE | integer |
tme | SMF79TME | TIME RECORD WRITTEN | time |
dte | SMF79DTE | DATE RECORD WRITTEN | date |
sid | SMF79SID | SYSTEM ID FROM INSTALLATION | string |
ssi | SMF79SSI | SUBSYSTEM ID (RMF ) | string |
sty | SMF79STY | SUBTYPE | integer |
trn | SMF79TRN | NUMBER OF TRIPLETS IN THIS REC | integer |
prs | SMF79PRS | OFFSET TO RMF PRODUCT SECTION | integer |
prl | SMF79PRL | LENGTH OF RMF PRODUCT SECTION | integer |
prn | SMF79PRN | NUMBER OF RMF PRODUCT SECTIONS | integer |
mcs | SMF79MCS | OFFSET TO MONITOR II CONTROL SECTION | integer |
mcl | SMF79MCL | LENGTH OF MONITOR II CONTROL SECTION | integer |
mcn | SMF79MCN | NUMBER OF MONITOR II CONTROL SECTION | integer |
ass | SMF79ASS | OFFSET TO DATA SECTION | integer |
asl | SMF79ASL | LENGTH OF DATA SECTION | integer |
asn | SMF79ASN | NUMBER OF DATA SECTION | integer |
dcs | SMF79DCS | OFFSET TO DATA CONTROL SECTION | integer |
dcl | SMF79DCL | LENGTH OF DATA CONTROL SECTION | integer |
dcn | SMF79DCN | NUMBER OF DATA CONTROL SECTION | integer |
qss | SMF79QSS | OFFSET IOQ GLOBAL SECTION | integer |
qsl | SMF79QSL | LENGTH IOQ GLOBAL SECTION | integer |
qsn | SMF79QSN | NUMBER IOQ GLOBAL SECTION | integer |
RMF Product Section
Name | Based on | Description | Type/Format |
---|---|---|---|
mfv | SMF79MFV | RMF version number | integer |
prd | SMF79PRD | Product name | string |
ist | SMF79IST | Time monitor interval start | time |
dat | SMF79DAT | Date monitor interval start | date |
int | SMF79INT | Duration of monitor interval | time |
sam | SMF79SAM | Number of samples | integer |
fla flag | SMF79FLA | Flags | string |
cnv | fla | Data converted from version 2 | |
invalid_samples | fla | Invalid samples to be skipped | |
m3r | fla | Record was written by RMF Monitor III | |
interval_smf_control | fla | Interval was under SMF control | |
lower_service_level | fla | SMF record converted to lower service level. Bit is set by SMF record retrieval service GRBSMFR. | |
higher_service_level | fla | SMF record converted to higher release or service level. Bit is set by SMF record retrieval service GRBSMFR. | |
altvm | fla | Running under an alternate virtual machine environment | |
ziip_boost | fla | zIIP boost was active during entire interval | |
speed_boost | fla | Speed boost was active during entire interval | |
boost_class virtual | fla | Boost class is set at end of interval, valid only when zIIP boost and/or Speed boost is active: 001 IPL, 010 Shutdown, 011 Recovery Process | |
cyc | SMF79CYC | Sampling cycle length | time |
mvs | SMF79MVS | MVS software level (consists of an acronym and the version, release, and modification level - ZVvvrrmm) | string |
iml | SMF79IML | Indicates the type of processor complex on which data measurements were taken. X'03’ = 9672, zSeries | integer |
prf flag | SMF79PRF | Processor flags | string |
expanded_stor | prf | System has expanded storage | |
escon_ch | prf | Equipped with ESCON channel | |
escon_dir | prf | ESCON Director in configuration | |
arch_mode | prf | System in z/ARCH mode | |
zaap_inst | prf | At least one zAAP is currently installed | |
ziip_inst | prf | At least one zIIP is currently installed | |
dat_facility1 | prf | Enhanced DAT facility 1 | |
dat_facility2 | prf | Enhanced DAT facility 2 | |
ptn | SMF79PTN | PR/SM partition number | string |
srl | SMF79SRL | SMF record level | integer |
iet | SMF79IET | Interval expiration time token | date-time |
lgo | SMF79LGO | Offset GMT to local time | integer |
rao | SMF79RAO | Offset to reassembly area relative to start of RMF product section | integer |
ral | SMF79RAL | Length of reassembly area. Area consists of a fixed header and a variable number of information blocks. Length depends on the record type/subtype, but is fixed for a specific type/subtype | integer |
reassembly_area processed | SMF79RAN | Number of reassembly area. This field is used to indicate whether SMF record is broken. If 0, record is not broken. If 1, record is broken. Offset and length are only valid if SMFxxRAN is 1. Reassembly area is only present in broken records. | integer |
oil | SMF79OIL | Original interval length as defined in the session or by SMF (in seconds) | integer |
syn | SMF79SYN | SYNC value in seconds | integer |
gie | SMF79GIE | Projected gathering interval end GMT time | date-time |
xnm | SMF79XNM | Sysplex name as defined in ECVTSPLX | string |
snm | SMF79SNM | System name for current system as defined in CVTSNAME | string |
Common record 79 header
Name | Based on | Description | Type/Format |
---|---|---|---|
r79gtod | R79GTOD | Time when the call to data gatherer was issued | time |
r79lf2 flag | R79LF2 | Flag byte | string |
relocate_section_deficient | r79lf2 | Not enough relocate section to complete data gathering | |
report_sorted_sg | r79lf2 | Report sorted by SG | |
rsm_data_invalid | r79lf2 | Invalid RSM data obtained | |
goal_mode | r79lf2 | System is in GOAL mode | |
tranx_data_invalid | r79lf2 | Invalid transaction data | |
srm_mode_changed | r79lf2 | SRM mode changed | |
invalid_data | r79lf2 | inval. data fr. Mon I (DEV PGSP IOQ) | |
device_data_incomplete | r79lf2 | Incomplete device data due to too many devices | |
r79ses | R79SES | Session name | string |
r79user | R79USER | User field | integer |
r79rid | R79RID | Measurement name | string |
r79ctxtl | R79CTXTL | Length of command text | integer |
r79ctext | R79CTEXT | Command text | string |
r79dtxtl | R79DTXTL | Length default DR text | integer |
r79dtext | R79DTEXT | Default DR text | string |
r79ist | R79IST | Monitor I interval start time | time |
r79tsr | R79TSR | Total number of small records | integer |
r79tot | R79TOT | Total number of data sections in large record | integer |
r79nxt | R79NXT | Number of data sections in following small records | integer |
r79iwmtk | R79IWMTK | Token returned from IWMRCOLL service | string |
MAPPING OF DEVICE DATA SECTION
Name | Based on | Description | Type/Format |
---|---|---|---|
r799num | R799NUM | DEVICE NUMBER | string |
r799lcu | R799LCU | LOGICAL CONTROL UNIT NUMBER | integer |
r799cnf flag | R799CNF | DEVICE FLAGS | string |
qlength_invalid | r799cnf | =1 IF IOS Q-LENGTH INVALID | |
no_lcud_info | r799cnf | =1 IF NO LCUD INFORMATION | |
cmb_data_invalid | r799cnf | =1 IF CMB DATA INVALID | |
device_time_invalid | r799cnf | =1 IF DEVICE CONNECT OR PENDING OR DISCONNECT TIME IS INVALID | |
data_invalid | r799cnf | DATA INVALID, VARIED ON OR OFF, OR DYNAMIC RECONFIGURATION | |
online_interval_end | r799cnf | =1 FOR ONLINE AT END OF INTERVAL | |
mounted_volume_sn | R799SER | VOLUME SERIAL NUMBER OF MOUNTED VOLUME | string |
r799typ | R799TYP | UNIT TYPE FROM UCBTYP FIELD | string |
r799nux | R799NUX | Number of exposures (if multiple). In case of a HyperPAV base device, R799HPV = 1, number of accumulated HyperPAV aliases | integer |
r799ssc | R799SSC | START SUBCHANNEL (SSCH) COUNT | integer |
r799mec | R799MEC | MEASUREMENT EVENT COUNT (NUMBER OF SSCH FOR WHICH CONNECT, PENDING, AND ACTIVE TIME WERE STORED | integer |
r799cnn | R799CNN | DEVICE CONNECT TIME | integer |
r799pen | R799PEN | FUNCTION PENDING TIME | integer |
r799atv | R799ATV | FUNCTION ACTIV TIME | integer |
r799dis | R799DIS | DEVICE DISCONNECT TIME | integer |
r799que | R799QUE | NUMBER OF REQUESTS QUEUED IN IOS FOR THIS DEVICE | integer |
r799utl | R799UTL | NUMBER OF SAMPLES WHEN THE DEVICE WAS RESERVED, BUT AN SSCH HAD NOT BEEN ISSUED | integer |
r799rsv | R799RSV | NUMBER OF SAMPLES DURING THE INTERVAL THAT INDICATED THAT THE DEVICE WAS RESERVED | integer |
r799alc | R799ALC | NUMBER OF SAMPLES DURING THE INTERVAL THAT INDICATED THAT THE DEVICE WAS ALLOCATED | integer |
r799dvb | R799DVB | device busy delay time (3090,9021,9121,9221 support) | integer |
r799cnx flag | R799CNX | Device flag extension | string |
parallel_access_vol | r799cnx | =1 If base exposure of a Parallel Access Volume | |
alias_number_change | r799cnx | =1 If number of alias exposures changed | |
timing_inactive | r799cnx | Timing facility not active | |
ecmb_mode | r799cnx | =1 ECMB mode | |
model_data_inavaliable_stsch | r799cnx | =1 model dependent data not available by STSCH | |
command_response_time | r799cnx | =1 Initial command response time available | |
hyperpav_base_device | r799cnx | =1 HyperPAV base device | |
interrupt_delay_time | r799cnx | =1 Interrupt delay time available | |
sorage_group | R799SGN | Storage Group Name | string |
r799nda | R799NDA | Total number of allocations in effect for the device | integer |
r799cmr | R799CMR | Command response time in units of 128 microseconds | integer |
r799pct | R799PCT | Number of unsuccessful PAV samples | integer |
r799psm | R799PSM | Number of successful PAV samples | integer |
r799idt | R799IDT | Interrupt delay time in units of 128 microseconds. This field is zero if not supported by the hardware. | integer |
r799cuq | R799CUQ | Control Unit Queuing Time | integer |
r799cn2 flag | R799CN2 | Device flag extension 2 | string |
device_ficon | r799cn2 | Device connected to FICON | |
r799scs | R799SCS | Subchannel set the device is situated | integer |
r799nm2 | R799NM2 | Device number same as R799NUM | string |
r799ios | R799IOS | IOS Queue time in microseconds | integer |