IBM SMF Explorer
GitHub Toggle Dark/Light/Auto mode Toggle Dark/Light/Auto mode Toggle Dark/Light/Auto mode Back to homepage

SMF 79 Subtype 9

Virtual fields

Name Based on Description
timestamp date
time
Record Timestamp
boost_class fla Boost class is set at end of interval, valid only when zIIP boost and/or Speed boost is active: 001 IPL, 010 Shutdown, 011 Recovery Process

Record fields

Name Based on Description Type/Format
date SMF79DTE Date of Record date
time SMF79TME Time of Record time
timestamp virtual date
time
Record Timestamp
len SMF79LEN SMF RECORD LENGTH. ZERO AFTER GRBSMFR REASSEMBLY integer
seg SMF79SEG SEGMENT DESCRIPTOR integer
flg flag SMF79FLG SYSTEM INDICATOR FLAGS string
rrf flg NEW RECORD FORMAT
sut flg SUBTYPES USED
v4 flg MVS/ESA V4 IF ON
esa flg MVS/ESA IF ON
vxa flg MVS/XA IF ON
os flg OPERATING SYSTEM IS OS/VS2
bfy flg SYSTEM RUNNING IN PR/SM MODE
rty SMF79RTY RECORD TYPE integer
tme SMF79TME TIME RECORD WRITTEN time
dte SMF79DTE DATE RECORD WRITTEN date
sid SMF79SID SYSTEM ID FROM INSTALLATION string
ssi SMF79SSI SUBSYSTEM ID (RMF ) string
sty SMF79STY SUBTYPE integer
trn SMF79TRN NUMBER OF TRIPLETS IN THIS REC integer
prs SMF79PRS OFFSET TO RMF PRODUCT SECTION integer
prl SMF79PRL LENGTH OF RMF PRODUCT SECTION integer
prn SMF79PRN NUMBER OF RMF PRODUCT SECTIONS integer
mcs SMF79MCS OFFSET TO MONITOR II CONTROL SECTION integer
mcl SMF79MCL LENGTH OF MONITOR II CONTROL SECTION integer
mcn SMF79MCN NUMBER OF MONITOR II CONTROL SECTION integer
ass SMF79ASS OFFSET TO DATA SECTION integer
asl SMF79ASL LENGTH OF DATA SECTION integer
asn SMF79ASN NUMBER OF DATA SECTION integer
dcs SMF79DCS OFFSET TO DATA CONTROL SECTION integer
dcl SMF79DCL LENGTH OF DATA CONTROL SECTION integer
dcn SMF79DCN NUMBER OF DATA CONTROL SECTION integer
qss SMF79QSS OFFSET IOQ GLOBAL SECTION integer
qsl SMF79QSL LENGTH IOQ GLOBAL SECTION integer
qsn SMF79QSN NUMBER IOQ GLOBAL SECTION integer

Maps and sections

SMF79PRO

RMF Product Section

Name Based on Description Type/Format
mfv SMF79MFV RMF version number integer
prd SMF79PRD Product name string
ist SMF79IST Time monitor interval start time
dat SMF79DAT Date monitor interval start date
int SMF79INT Duration of monitor interval time
sam SMF79SAM Number of samples integer
fla flag SMF79FLA Flags string
cnv fla Data converted from version 2
invalid_samples fla Invalid samples to be skipped
m3r fla Record was written by RMF Monitor III
interval_smf_control fla Interval was under SMF control
lower_service_level fla SMF record converted to lower service level. Bit is set by SMF record retrieval service GRBSMFR.
higher_service_level fla SMF record converted to higher release or service level. Bit is set by SMF record retrieval service GRBSMFR.
altvm fla Running under an alternate virtual machine environment
ziip_boost fla zIIP boost was active during entire interval
speed_boost fla Speed boost was active during entire interval
boost_class virtual fla Boost class is set at end of interval, valid only when zIIP boost and/or Speed boost is active: 001 IPL, 010 Shutdown, 011 Recovery Process
cyc SMF79CYC Sampling cycle length time
mvs SMF79MVS MVS software level (consists of an acronym and the version, release, and modification level - ZVvvrrmm) string
iml SMF79IML Indicates the type of processor complex on which data measurements were taken. X'03’ = 9672, zSeries integer
prf flag SMF79PRF Processor flags string
expanded_stor prf System has expanded storage
escon_ch prf Equipped with ESCON channel
escon_dir prf ESCON Director in configuration
arch_mode prf System in z/ARCH mode
zaap_inst prf At least one zAAP is currently installed
ziip_inst prf At least one zIIP is currently installed
dat_facility1 prf Enhanced DAT facility 1
dat_facility2 prf Enhanced DAT facility 2
ptn SMF79PTN PR/SM partition number string
srl SMF79SRL SMF record level integer
iet SMF79IET Interval expiration time token date-time
lgo SMF79LGO Offset GMT to local time integer
rao SMF79RAO Offset to reassembly area relative to start of RMF product section integer
ral SMF79RAL Length of reassembly area. Area consists of a fixed header and a variable number of information blocks. Length depends on the record type/subtype, but is fixed for a specific type/subtype integer
reassembly_area processed SMF79RAN Number of reassembly area. This field is used to indicate whether SMF record is broken. If 0, record is not broken. If 1, record is broken. Offset and length are only valid if SMFxxRAN is 1. Reassembly area is only present in broken records. integer
oil SMF79OIL Original interval length as defined in the session or by SMF (in seconds) integer
syn SMF79SYN SYNC value in seconds integer
gie SMF79GIE Projected gathering interval end GMT time date-time
xnm SMF79XNM Sysplex name as defined in ECVTSPLX string
snm SMF79SNM System name for current system as defined in CVTSNAME string

R79CHL

Common record 79 header

Name Based on Description Type/Format
r79gtod R79GTOD Time when the call to data gatherer was issued time
r79lf2 flag R79LF2 Flag byte string
relocate_section_deficient r79lf2 Not enough relocate section to complete data gathering
report_sorted_sg r79lf2 Report sorted by SG
rsm_data_invalid r79lf2 Invalid RSM data obtained
goal_mode r79lf2 System is in GOAL mode
tranx_data_invalid r79lf2 Invalid transaction data
srm_mode_changed r79lf2 SRM mode changed
invalid_data r79lf2 inval. data fr. Mon I (DEV PGSP IOQ)
device_data_incomplete r79lf2 Incomplete device data due to too many devices
r79ses R79SES Session name string
r79user R79USER User field integer
r79rid R79RID Measurement name string
r79ctxtl R79CTXTL Length of command text integer
r79ctext R79CTEXT Command text string
r79dtxtl R79DTXTL Length default DR text integer
r79dtext R79DTEXT Default DR text string
r79ist R79IST Monitor I interval start time time
r79tsr R79TSR Total number of small records integer
r79tot R79TOT Total number of data sections in large record integer
r79nxt R79NXT Number of data sections in following small records integer
r79iwmtk R79IWMTK Token returned from IWMRCOLL service string

R799ELEM

MAPPING OF DEVICE DATA SECTION

Name Based on Description Type/Format
r799num R799NUM DEVICE NUMBER string
r799lcu R799LCU LOGICAL CONTROL UNIT NUMBER integer
r799cnf flag R799CNF DEVICE FLAGS string
qlength_invalid r799cnf =1 IF IOS Q-LENGTH INVALID
no_lcud_info r799cnf =1 IF NO LCUD INFORMATION
cmb_data_invalid r799cnf =1 IF CMB DATA INVALID
device_time_invalid r799cnf =1 IF DEVICE CONNECT OR PENDING OR DISCONNECT TIME IS INVALID
data_invalid r799cnf DATA INVALID, VARIED ON OR OFF, OR DYNAMIC RECONFIGURATION
online_interval_end r799cnf =1 FOR ONLINE AT END OF INTERVAL
mounted_volume_sn R799SER VOLUME SERIAL NUMBER OF MOUNTED VOLUME string
r799typ R799TYP UNIT TYPE FROM UCBTYP FIELD string
r799nux R799NUX Number of exposures (if multiple). In case of a HyperPAV base device, R799HPV = 1, number of accumulated HyperPAV aliases integer
r799ssc R799SSC START SUBCHANNEL (SSCH) COUNT integer
r799mec R799MEC MEASUREMENT EVENT COUNT (NUMBER OF SSCH FOR WHICH CONNECT, PENDING, AND ACTIVE TIME WERE STORED integer
r799cnn R799CNN DEVICE CONNECT TIME integer
r799pen R799PEN FUNCTION PENDING TIME integer
r799atv R799ATV FUNCTION ACTIV TIME integer
r799dis R799DIS DEVICE DISCONNECT TIME integer
r799que R799QUE NUMBER OF REQUESTS QUEUED IN IOS FOR THIS DEVICE integer
r799utl R799UTL NUMBER OF SAMPLES WHEN THE DEVICE WAS RESERVED, BUT AN SSCH HAD NOT BEEN ISSUED integer
r799rsv R799RSV NUMBER OF SAMPLES DURING THE INTERVAL THAT INDICATED THAT THE DEVICE WAS RESERVED integer
r799alc R799ALC NUMBER OF SAMPLES DURING THE INTERVAL THAT INDICATED THAT THE DEVICE WAS ALLOCATED integer
r799dvb R799DVB device busy delay time (3090,9021,9121,9221 support) integer
r799cnx flag R799CNX Device flag extension string
parallel_access_vol r799cnx =1 If base exposure of a Parallel Access Volume
alias_number_change r799cnx =1 If number of alias exposures changed
timing_inactive r799cnx Timing facility not active
ecmb_mode r799cnx =1 ECMB mode
model_data_inavaliable_stsch r799cnx =1 model dependent data not available by STSCH
command_response_time r799cnx =1 Initial command response time available
hyperpav_base_device r799cnx =1 HyperPAV base device
interrupt_delay_time r799cnx =1 Interrupt delay time available
sorage_group R799SGN Storage Group Name string
r799nda R799NDA Total number of allocations in effect for the device integer
r799cmr R799CMR Command response time in units of 128 microseconds integer
r799pct R799PCT Number of unsuccessful PAV samples integer
r799psm R799PSM Number of successful PAV samples integer
r799idt R799IDT Interrupt delay time in units of 128 microseconds. This field is zero if not supported by the hardware. integer
r799cuq R799CUQ Control Unit Queuing Time integer
r799cn2 flag R799CN2 Device flag extension 2 string
device_ficon r799cn2 Device connected to FICON
r799scs R799SCS Subchannel set the device is situated integer
r799nm2 R799NM2 Device number same as R799NUM string
r799ios R799IOS IOS Queue time in microseconds integer