ibmi_device_vary – Vary on or off target device
Synopsis
Vary on or off target device.
For non-IBM i targets, no need.
Parameters
- become_user
The name of the user profile that the IBM i task will run under.
Use this option to set a user with desired privileges to run the task.
required: falsetype: str- become_user_password
Use this option to set the password of the user specified in
become_user
.required: falsetype: str- device_list
The name of the device.
If the one of the device is IASP device, the become_user and become_user_password will be ignored.
required: Truetype: listelements: str- extra_parameters
Extra parameter is appended at the end of VARYCFG command.
required: falsetype: strdefault:- joblog
If set to
true
, append JOBLOG to stderr/stderr_lines.required: falsetype: bool- status
on
/off
are idempotent actions that will not run commands unless necessary.reset
will always bounce the service.At least one of status are required.
required: Truetype: strchoices: *ON, *OFF, *RESET, *ALLOCATE, UNPROTECTED, *DEALLOCATE
Examples
- name: start host server service
ibm.power_ibmi.ibmi_device_vary:
device_list: ['IASP1', 'IASP2']
status: '*ON'
joblog: True
become_user: 'USER1'
become_user_password: 'yourpassword'
See Also
See also
service_module
Return Values
- job_log
The IBM i job log of the task executed.returned: alwaystype: listsample:[{"FROM_INSTRUCTION": "318F", "FROM_LIBRARY": "QSYS", "FROM_MODULE": "", "FROM_PROCEDURE": "", "FROM_PROGRAM": "QWTCHGJB", "FROM_USER": "CHANGLE", "MESSAGE_FILE": "QCPFMSG", "MESSAGE_ID": "CPD0912", "MESSAGE_LIBRARY": "QSYS", "MESSAGE_SECOND_LEVEL_TEXT": "Cause . . . . . : This message is used by application programs as a general escape message.", "MESSAGE_SUBTYPE": "", "MESSAGE_TEXT": "Printer device PRT01 not found.", "MESSAGE_TIMESTAMP": "2020-05-20-21.41.40.845897", "MESSAGE_TYPE": "DIAGNOSTIC", "ORDINAL_POSITION": "5", "SEVERITY": "20", "TO_INSTRUCTION": "9369", "TO_LIBRARY": "QSYS", "TO_MODULE": "QSQSRVR", "TO_PROCEDURE": "QSQSRVR", "TO_PROGRAM": "QSQSRVR"}]- start
The command execution start time.returned: alwaystype: strsample: 2019-12-02 11:07:53.757435- end
The command execution end time.returned: alwaystype: strsample: 2019-12-02 11:07:54.064969- delta
The command execution delta time.returned: alwaystype: strsample: 0:00:00.307534- stdout
The command standard output.returned: alwaystype: strsample: +++ success VRYCFG CFGOBJ(IASP1) CFGTYPE(*DEV) STATUS(*ON)- stderr
The command standard error.returned: alwaystype: strsample: CPF2111:Library TESTLIB already exists- cmd
The command executed by the task.returned: alwaystype: strsample: VRYCFG CFGOBJ(IASP1) CFGTYPE(*DEV) STATUS(*ON)- rc
The command return code (0 means success, non-zero means failure).returned: alwaystype: intsample: 255- stdout_lines
The command standard output split in lines.returned: alwaystype: listsample:["+++ success VRYCFG CFGOBJ(IASP1) CFGTYPE(*DEV) STATUS(*ON)"]- stderr_lines
The command standard error split in lines.returned: alwaystype: listsample:["CPF2111:Library TESTLIB already exists."]